From d1fa8ee6761f8c7548389c86b98200ea16a234e9 Mon Sep 17 00:00:00 2001 From: Steffen Knott Date: Mon, 22 Feb 2021 22:38:16 +0100 Subject: [PATCH] Update go-eCharger API v1 DE.md Old version made it hard to find out which parameters are read only and which are read/write. Adding this info to the table makes way more sense imho. The old listing in section 3 may be dropped (was missing some variables btw, I marked them in the table with a "?"). --- go-eCharger API v1 DE.md | 156 ++++++++++++++++++--------------------- 1 file changed, 72 insertions(+), 84 deletions(-) diff --git a/go-eCharger API v1 DE.md b/go-eCharger API v1 DE.md index 5c5026e..b4d7456 100644 --- a/go-eCharger API v1 DE.md +++ b/go-eCharger API v1 DE.md @@ -93,93 +93,81 @@ Zusätzlich zu diesen Parametern können auch ohne vorherige Ankündigung und je **Erklärung Format:** alle Parameter werden im JSON Objekt als String gesendet (in Anführungszeichen). Die meisten dieser Parameter können in ein Integer Format konvertiert werden. Der bei Format angegebene Datentyp zeigt die zu erwartende Größe. Sollte der String nicht in den angegebenen Datentyp konvertiert werden, soll ein Kommunikationsfehler angezeigt werden. -| Parameter | Format | Erklärung | -| ------------------------------------------------------------------- | ---------- | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- | -| version | String (1) | **JSON Format.**
"B": Normalfall
"C":Wenn Ende-zu-Ende Verschlüsselung aktiviert | -| rbc | uint32_t | **reboot_counter:** Zählt die Anzahl der Bootvorgänge. Wird mit der Ende-zu-Ende Verschlüsselung als Schutz gegen Replay Attacken gesendet. | -| rbt | uint32_t | **reboot_timer:** Zählt die Millisekunden seit dem letzten Bootvorgang. Wird mit der Ende-zu-Ende Verschlüsselung als Schutz gegen Replay Attacken gesendet. Läuft nach 49 Tage über und erhöht dabei den reboot_counter. | -| car | uint8_t | **Status PWM Signalisierung**
1: Ladestation bereit, kein Fahrzeug
2: Fahrzeug lädt
3: Warte auf Fahrzeug
4: Ladung beendet, Fahrzeug noch verbunden | -| amp | uint8_t | Ampere Wert für die PWM Signalisierung in ganzen Ampere von **6-32A** | -| amx | uint8_t | Ampere Wert für die PWM Signalisierung in ganzen Ampere von **6-32A**. Wird nicht auf dem Flash persistiert, verhält sich sonst aber gleich wie amp. Nach dem reboot wird amp auf den letzten Wert zurückgesetzt, der mit amp gesetzt wurde. Für PV Regelung empfohlen. | -| err | uint8_t | **error:**
1: RCCB (Fehlerstromschutzschalter)
3: PHASE (Phasenstörung)
8: NO_GROUND (Erdungserkennung)
10, default: INTERNAL (sonstiges) | -| ast | uint8_t | **access_state:** Zugangskontrolle.
0: Offen
1: RFID / App benötigt
2: Strompreis / automatisch | -| alw | uint8_t | **allow_charging:** PWM Signal darf anliegen
0: nein
1: ja | -| stp | uint8_t | **stop_state:** ​Automatische Abschaltung
0: deaktiviert
2: nach kWh abschalten kWh | -| cbl | uint8_t | **Typ2 ​Kabel Ampere codierung**
13-32: Ampere Codierung
0: kein Kabel | -| pha | uint8_t | **Phasen** vor und nach dem Schütz
binary flags: 0b00ABCDEF
A ... phase 3, vor dem Schütz
B ... phase 2 vor dem Schütz
C ... phase 1 vor dem Schütz
D ... phase 3 nach dem Schütz
E ... phase 2 nach dem Schütz
F ... phase 1 nach dem Schütz
pha | 0b00001000: Phase 1 ist vorhanden
pha | 0b00111000: Phase1-3 ist vorhanden | -| tmp | uint8_t | **Temperatur​** des controller in °C | -| dws | uint32_t | **Geladene Energiemenge** in Deka-Watt-Sekunden
Beispiel: 100'000 bedeutet, 1'000'000 Ws (= 277Wh = 0.277kWh)
wurden in diesem Ladevorgang geladen. | -| dwo | uint16_t | **Abschaltwert** in 0.1kWh wenn stp==2, für dws Parameter
Beispiel: 105 fur 10,5kWh
Ladebox-Logik: if(dwo!=0 && dws/36000>=dwo)alw=0 | -| adi | uint8_t | **adapter_in:** Ladebox ist mit Adapter angesteckt
0: NO_ADAPTER
1: 16A_ADAPTER | -| uby | uint8_t | **unlocked_by:** Nummer der RFID Karte, die den jetzigen
Ladevorgang freigeschalten hat | -| eto | uint32_t | **energy_total:** Gesamt geladene Energiemenge in 0.1kWh
Beispiel: 130 bedeutet 13kWh geladen | -| wst | uint8_t | **wifi_state:** WLAN Verbindungsstatus
3: verbunden
default: nicht verbunden | -| nrg | array[15] | Array mit Werten des Strom- und Spannungssensors
nrg[0]: Spannung auf L1 in volts
nrg[1]: Spannung auf L2 in volts
nrg[2]: Spannung auf L3 in volts
nrg[3]: Spannung auf N in volts
nrg[4]: Ampere auf L1 in 0.1A (123 entspricht 12.3A)
nrg[5]: Ampere auf L2 in 0.1A
nrg[6]: Ampere auf L3 in 0.1A
nrg[7]: Leistung auf L1 in 0.1kW (36 entspricht 3.6kW)
nrg[8]: Leistung auf L2 in 0.1kW
nrg[9]: Leistung auf L3 in 0.1kW
nrg[10]: Leistung auf N in 0.1kW
nrg[11]: Leistung gesamt 0.01kW (360 entspricht 3.6kW)
nrg[12]: Leistungsfaktor auf L1 in%
nrg[13]: Leistungsfaktor auf L2 in%
nrg[14]: Leistungsfaktor auf L3 in%
nrg[15]: Leistungsfaktor auf N in%

App Logik:
if(Math.floor(pha/8) ==1 &&
parseInt(nrg[3])>parseInt(nrg[0])){
nrg[0]=nrg[3]
nrg[7]=nrg[10]
nrg[12]=nrg[15]
} | -| fwv | String | **Firmware Version**
Beispiel: "020-rc1" | -| sse | String | **Seriennummer** als %06d formatierte Zahl
Example: "000001" | -| wss | String | WLAN **SSID**
Beispiel: "Mein Heimnetzwerk" | -| wke | String | WLAN **Key**
Beispiel: "**\*\*\*\***" für fwv ab 020
Beispiel: "password" für fwv vor 020 | -| wen | uint8_t | **wifi_enabled:** Wi-Fi aktiviert
0: deaktiviert
1: aktiviert | -| tof | uint8_t | **time_offset:** Zeitzone in Stunden für interne batteriegestützte Uhr +100
Beispiel: 101 entspricht GMT + 1 | -| tds | uint8_t | **Daylight saving time offset** (Sommerzeit) in Stunden
Beispiel: 1 für Mitteleuropa | -| lbr | uint8_t | **LED Helligkeit** von 0-255
0: LED aus
255: LED Helligkeit maximal | -| aho | uint8_t | Minimale Anzahl von Stunden in der mit "Strompreis - automatisch" geladen werden muss.
Beispiel: 2 ("Auto ist nach 2 Stunden voll genug") | -| afi | uint8_t | Stunde (Uhrzeit) in der mit "Strompreis - automatisch" die Ladung mindestens aho Stunden gedauert haben muss.
Beispiel: 7 ("Fertig bis 7:00, also davor mindestens 2 Stunden geladen") | -| azo | uint8_t | Awattar Preiszone
0: Österreich
1: Deutschland | -| ama | uint8_t | Absolute max. Ampere: Maximalwert für Ampere Einstellung
Beispiel: 20 (Einstellung auf mehr als 20A in der App nicht möglich) | -| al1 | uint8_t | Ampere Level 1 für Druckknopf am Gerät.
6-32: Ampere Stufe aktiviert
0: Stufe deaktivert (wird übersprungen) | -| al2 | uint8_t | Ampere Level 2 für Druckknopf am Gerät.
Muss entweder 0 oder > al1 sein | -| al3 | uint8_t | Ampere Level 3 für Druckknopf am Gerät.
Muss entweder 0 oder > al2 sein | -| al4 | uint8_t | Ampere Level 4 für Druckknopf am Gerät.
Muss entweder 0 oder > al3 sein | -| al5 | uint8_t | Ampere Level 5 für Druckknopf am Gerät.
Muss entweder 0 oder > al4 sein | -| cid | uint24_t | Color idle:**Farbwert für Standby** (kein Auto angesteckt) als Zahl
Beispiel: parseInt("#00FFFF"): 65535 (blau/grün, Standard) | -| cch | uint24_t | Color charging: Farbwert für Ladevorgang aktiv, als Zahl
Beispiel: parseInt("#0000FF"):255 (blau, Standard) | -| cfi | uint24_t | Color idle: **Farbwert für Ladevorgang abgeschlossen** als Zahl
Beispiel: parseInt("#00FF00"): 65280(grün, Standard) | -| lse | uint8_t | **led_save_energy:** LED automatisch nach 10 Sekunden abschalten
0: Energiesparfunktion deaktiviert
1: Energiesparfunktion aktiviert | -| ust | uint8_t | **unlock_state:** Kabelverriegelung Einstellung
0: Verriegeln solange Auto angesteckt
1: Nach Ladevorgang automatisch entriegeln
2: Kabel immer verriegelt lassen | -| wak | String | WLAN **Hotspot Password**
Beispiel: "abdef0123456" | -| r1x | uint8_t | **Flags**
0b1: HTTP Api im WLAN Netzwerk aktiviert (0:nein, 1:ja)
0b10: Ende-zu-Ende Verschlüsselung aktiviert (0: nein, 1: ja) | -| dto | uint8_t | **Restzeit** in Millisekunden verbleibend auf Aktivierung durch Strompreise App-logik:
if (json.car==1) message = "Zuerst Auto anstecken"
else message = "Restzeit: …" | -| nmo | uint8_t | **Norwegen-Modus** aktiviert
0: deaktiviert (Erdungserkennung aktiviert)
1: aktiviert (Erdungserkennung deaktiviert) | -| eca
ecr
ecd
ec4
ec5
ec6
ec7
ec8
ec9
ec1 | uint32_t | Geladene **Energiemenge pro RFID Karte** von 1-10
Beispiel: eca == 1400: 140kWh auf Karte 1 geladen
Beispiel: ec7 == 1400: 140kWh auf Karte 7 geladen
Beispiel: ec1 == 1400: 140kWh auf Karte 10 geladen | -| rca
rcr
rcd
rc4
rc5
rc6
rc7
rc8
rc9
rc1 | String | **RFID Karte ID** von 1-10 als string
Format und Länge: variabel, je nach Version | -| rna
rnm
rne
rn4
rn5
rn6
rn7
rn8
rn9
rn1 | String | **RFID Karte Name** von 1-10
Maximallänge: 10 Zeichen | -| tme | String |**Aktuelle Uhrzeit**, formatiert als ddmmyyhhmm
0104191236 entspricht to 01.04.2019 12:36 | -| sch | String | **Scheduler einstellungen** (base64 encodiert)
Funktionen zum encodieren und decodieren gibt es hier:
https://gist.github.com/peterpoetzi/6cd2fad2a915a2498776912c5aa137a8
Die Einstellungen können so gesetzt werden:
r21=Math.floor(encode(1))
r31=Math.floor(encode(2))
r41=Math.floor(encode(3))
DEin direktes Setzen von sch= wird nicht unterstützt | -| sdp | uint8_t | **Scheduler double press:** Aktiviert Ladung nach doppeltem Drücken des Button, wenn die Ladung gerade durch den Scheduler unterbrochen wurde
0: Funktion deaktiviert
1: Ladung sofort erlauben | -| upd | uint8_t | **Update available** (nur verfügbar bei Verbindung über go-e Server)
0: kein Update verfügbar
1: Update verfügbar | -| cdi | uint8_t | **Cloud disabled**
0: cloud enabled
1: cloud disabled | -| loe | uint8_t | **Lastmanagement enabled**
0: Lastmanagement deaktiviert
1: Lastmanagement über Cloud aktiviert | -| lot | uint8_t | **Lastmanagement Gruppe Total Ampere** | -| lom | uint8_t | **Lastmanagement minimale Amperezahl** | -| lop | uint8_t | **Lastmanagement Priorität** | -| log | String | **Lastmanagement Gruppen ID** | -| lon | uint8_t | **Lastmanagement: erwartete Anzahl von Ladestationen (derzeit nicht unterstützt)** | -| lof | uint8_t | **Lastmanagement Fallback Amperezahl** | -| loa | uint8_t | **Lastmanagement Ampere** (derzeitiger erlaubter Ladestrom)
wird vom Lastmanagement automatisch gesteuert | -| lch | uint32_t | **Lastmanagement: Sekunden seit letztem Stromfluss bei noch angestecktem Auto**
0 when charging is in progress | -| mce | uint8_t | **MQTT custom enabled**
Verbindung mit eigenen MQTT Server herstellen
0: Funktion deaktiviert
1: Funktion aktiviert | -| mcs | String(63) | **MQTT custom Server**
Hostname ohne Protokollangabe (z.B. test.mosquitto.org) | -| mcp | uint16_t | **MQTT custom Port**
z.B. 1883 | -| mcu | String(16) | **MQTT custom Username** | -| mck | String(16) | **MQTT custom key**
Für MQTT Authentifizierung | -| mcc | uint8_t | **MQTT custom connected**
0: nicht verbunden
1: verbunden Seite | +| Parameter | Format | Zugriff | Erklärung | +| ------------------------------------------------------------------- | ---------- | ------- | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- | +| version | String (1) | RO | **JSON Format.**
"B": Normalfall
"C":Wenn Ende-zu-Ende Verschlüsselung aktiviert | +| rbc | uint32_t | RO | **reboot_counter:** Zählt die Anzahl der Bootvorgänge. Wird mit der Ende-zu-Ende Verschlüsselung als Schutz gegen Replay Attacken gesendet. | +| rbt | uint32_t | RO | **reboot_timer:** Zählt die Millisekunden seit dem letzten Bootvorgang. Wird mit der Ende-zu-Ende Verschlüsselung als Schutz gegen Replay Attacken gesendet. Läuft nach 49 Tage über und erhöht dabei den reboot_counter. | +| car | uint8_t | RO | **Status PWM Signalisierung**
1: Ladestation bereit, kein Fahrzeug
2: Fahrzeug lädt
3: Warte auf Fahrzeug
4: Ladung beendet, Fahrzeug noch verbunden | +| amp | uint8_t | RW | Ampere Wert für die PWM Signalisierung in ganzen Ampere von **6-32A** | +| amx | uint8_t | RW | Ampere Wert für die PWM Signalisierung in ganzen Ampere von **6-32A**. Wird nicht auf dem Flash persistiert, verhält sich sonst aber gleich wie amp. Nach dem reboot wird amp auf den letzten Wert zurückgesetzt, der mit amp gesetzt wurde. Für PV Regelung empfohlen. | +| err | uint8_t | RO | **error:**
1: RCCB (Fehlerstromschutzschalter)
3: PHASE (Phasenstörung)
8: NO_GROUND (Erdungserkennung)
10, default: INTERNAL (sonstiges) | +| ast | uint8_t | RW | **access_state:** Zugangskontrolle.
0: Offen
1: RFID / App benötigt
2: Strompreis / automatisch | +| alw | uint8_t | RW | **allow_charging:** PWM Signal darf anliegen
0: nein
1: ja | +| stp | uint8_t | RW | **stop_state:** ​Automatische Abschaltung
0: deaktiviert
2: nach kWh abschalten kWh | +| cbl | uint8_t | RO | **Typ2 ​Kabel Ampere codierung**
13-32: Ampere Codierung
0: kein Kabel | +| pha | uint8_t | RO | **Phasen** vor und nach dem Schütz
binary flags: 0b00ABCDEF
A ... phase 3, vor dem Schütz
B ... phase 2 vor dem Schütz
C ... phase 1 vor dem Schütz
D ... phase 3 nach dem Schütz
E ... phase 2 nach dem Schütz
F ... phase 1 nach dem Schütz
pha | 0b00001000: Phase 1 ist vorhanden
pha | 0b00111000: Phase1-3 ist vorhanden | +| tmp | uint8_t | RO | **Temperatur​** des controller in °C | +| dws | uint32_t | RO | **Geladene Energiemenge** in Deka-Watt-Sekunden
Beispiel: 100'000 bedeutet, 1'000'000 Ws (= 277Wh = 0.277kWh)
wurden in diesem Ladevorgang geladen. | +| dwo | uint16_t | RW | **Abschaltwert** in 0.1kWh wenn stp==2, für dws Parameter
Beispiel: 105 fur 10,5kWh
Ladebox-Logik: if(dwo!=0 && dws/36000>=dwo)alw=0 | +| adi | uint8_t | RO | **adapter_in:** Ladebox ist mit Adapter angesteckt
0: NO_ADAPTER
1: 16A_ADAPTER | +| uby | uint8_t | RO | **unlocked_by:** Nummer der RFID Karte, die den jetzigen
Ladevorgang freigeschalten hat | +| eto | uint32_t | RO | **energy_total:** Gesamt geladene Energiemenge in 0.1kWh
Beispiel: 130 bedeutet 13kWh geladen | +| wst | uint8_t | RO | **wifi_state:** WLAN Verbindungsstatus
3: verbunden
default: nicht verbunden | +| nrg | array[15] | RO | Array mit Werten des Strom- und Spannungssensors
nrg[0]: Spannung auf L1 in volts
nrg[1]: Spannung auf L2 in volts
nrg[2]: Spannung auf L3 in volts
nrg[3]: Spannung auf N in volts
nrg[4]: Ampere auf L1 in 0.1A (123 entspricht 12.3A)
nrg[5]: Ampere auf L2 in 0.1A
nrg[6]: Ampere auf L3 in 0.1A
nrg[7]: Leistung auf L1 in 0.1kW (36 entspricht 3.6kW)
nrg[8]: Leistung auf L2 in 0.1kW
nrg[9]: Leistung auf L3 in 0.1kW
nrg[10]: Leistung auf N in 0.1kW
nrg[11]: Leistung gesamt 0.01kW (360 entspricht 3.6kW)
nrg[12]: Leistungsfaktor auf L1 in%
nrg[13]: Leistungsfaktor auf L2 in%
nrg[14]: Leistungsfaktor auf L3 in%
nrg[15]: Leistungsfaktor auf N in%

App Logik:
if(Math.floor(pha/8) ==1 &&
parseInt(nrg[3])>parseInt(nrg[0])){
nrg[0]=nrg[3]
nrg[7]=nrg[10]
nrg[12]=nrg[15]
} | +| fwv | String | RO | **Firmware Version**
Beispiel: "020-rc1" | +| sse | String | RO | **Seriennummer** als %06d formatierte Zahl
Example: "000001" | +| wss | String | RW | WLAN **SSID**
Beispiel: "Mein Heimnetzwerk" | +| wke | String | RW | WLAN **Key**
Beispiel: "**\*\*\*\***" für fwv ab 020
Beispiel: "password" für fwv vor 020 | +| wen | uint8_t | RW | **wifi_enabled:** Wi-Fi aktiviert
0: deaktiviert
1: aktiviert | +| tof | uint8_t | RW | **time_offset:** Zeitzone in Stunden für interne batteriegestützte Uhr +100
Beispiel: 101 entspricht GMT + 1 | +| tds | uint8_t | RW | **Daylight saving time offset** (Sommerzeit) in Stunden
Beispiel: 1 für Mitteleuropa | +| lbr | uint8_t | RW | **LED Helligkeit** von 0-255
0: LED aus
255: LED Helligkeit maximal | +| aho | uint8_t | RW | Minimale Anzahl von Stunden in der mit "Strompreis - automatisch" geladen werden muss.
Beispiel: 2 ("Auto ist nach 2 Stunden voll genug") | +| afi | uint8_t | RW | Stunde (Uhrzeit) in der mit "Strompreis - automatisch" die Ladung mindestens aho Stunden gedauert haben muss.
Beispiel: 7 ("Fertig bis 7:00, also davor mindestens 2 Stunden geladen") | +| azo | uint8_t | ? | Awattar Preiszone
0: Österreich
1: Deutschland | +| ama | uint8_t | RW | Absolute max. Ampere: Maximalwert für Ampere Einstellung
Beispiel: 20 (Einstellung auf mehr als 20A in der App nicht möglich) | +| al1 | uint8_t | RW | Ampere Level 1 für Druckknopf am Gerät.
6-32: Ampere Stufe aktiviert
0: Stufe deaktivert (wird übersprungen) | +| al2 | uint8_t | RW | Ampere Level 2 für Druckknopf am Gerät.
Muss entweder 0 oder > al1 sein | +| al3 | uint8_t | RW | Ampere Level 3 für Druckknopf am Gerät.
Muss entweder 0 oder > al2 sein | +| al4 | uint8_t | RW | Ampere Level 4 für Druckknopf am Gerät.
Muss entweder 0 oder > al3 sein | +| al5 | uint8_t | RW | Ampere Level 5 für Druckknopf am Gerät.
Muss entweder 0 oder > al4 sein | +| cid | uint24_t | RW | Color idle:**Farbwert für Standby** (kein Auto angesteckt) als Zahl
Beispiel: parseInt("#00FFFF"): 65535 (blau/grün, Standard) | +| cch | uint24_t | RW | Color charging: Farbwert für Ladevorgang aktiv, als Zahl
Beispiel: parseInt("#0000FF"):255 (blau, Standard) | +| cfi | uint24_t | RW | Color idle: **Farbwert für Ladevorgang abgeschlossen** als Zahl
Beispiel: parseInt("#00FF00"): 65280(grün, Standard) | +| lse | uint8_t | RW | **led_save_energy:** LED automatisch nach 10 Sekunden abschalten
0: Energiesparfunktion deaktiviert
1: Energiesparfunktion aktiviert | +| ust | uint8_t | RW | **unlock_state:** Kabelverriegelung Einstellung
0: Verriegeln solange Auto angesteckt
1: Nach Ladevorgang automatisch entriegeln
2: Kabel immer verriegelt lassen | +| wak | String | RW | WLAN **Hotspot Password**
Beispiel: "abdef0123456" | +| r1x | uint8_t | RW | **Flags**
0b1: HTTP Api im WLAN Netzwerk aktiviert (0:nein, 1:ja)
0b10: Ende-zu-Ende Verschlüsselung aktiviert (0: nein, 1: ja) | +| dto | uint8_t | RW | **Restzeit** in Millisekunden verbleibend auf Aktivierung durch Strompreise App-logik:
if (json.car==1) message = "Zuerst Auto anstecken"
else message = "Restzeit: …" | +| nmo | uint8_t | RW | **Norwegen-Modus** aktiviert
0: deaktiviert (Erdungserkennung aktiviert)
1: aktiviert (Erdungserkennung deaktiviert) | +| eca
ecr
ecd
ec4
ec5
ec6
ec7
ec8
ec9
ec1 | uint32_t | RO | Geladene **Energiemenge pro RFID Karte** von 1-10
Beispiel: eca == 1400: 140kWh auf Karte 1 geladen
Beispiel: ec7 == 1400: 140kWh auf Karte 7 geladen
Beispiel: ec1 == 1400: 140kWh auf Karte 10 geladen | +| rca
rcr
rcd
rc4
rc5
rc6
rc7
rc8
rc9
rc1 | String | RO | **RFID Karte ID** von 1-10 als string
Format und Länge: variabel, je nach Version | +| rna
rnm
rne
rn4
rn5
rn6
rn7
rn8
rn9
rn1 | String | RW | **RFID Karte Name** von 1-10
Maximallänge: 10 Zeichen | +| tme | String | ? | **Aktuelle Uhrzeit**, formatiert als ddmmyyhhmm
0104191236 entspricht to 01.04.2019 12:36 | +| sch | String | ? | **Scheduler einstellungen** (base64 encodiert)
Funktionen zum encodieren und decodieren gibt es hier:
https://gist.github.com/peterpoetzi/6cd2fad2a915a2498776912c5aa137a8
Die Einstellungen können so gesetzt werden:
r21=Math.floor(encode(1))
r31=Math.floor(encode(2))
r41=Math.floor(encode(3))
DEin direktes Setzen von sch= wird nicht unterstützt | +| sdp | uint8_t | ? | **Scheduler double press:** Aktiviert Ladung nach doppeltem Drücken des Button, wenn die Ladung gerade durch den Scheduler unterbrochen wurde
0: Funktion deaktiviert
1: Ladung sofort erlauben | +| upd | uint8_t | ? | **Update available** (nur verfügbar bei Verbindung über go-e Server)
0: kein Update verfügbar
1: Update verfügbar | +| cdi | uint8_t | ? | **Cloud disabled**
0: cloud enabled
1: cloud disabled | +| loe | uint8_t | ? | **Lastmanagement enabled**
0: Lastmanagement deaktiviert
1: Lastmanagement über Cloud aktiviert | +| lot | uint8_t | ? | **Lastmanagement Gruppe Total Ampere** | +| lom | uint8_t | ? | **Lastmanagement minimale Amperezahl** | +| lop | uint8_t | ? | **Lastmanagement Priorität** | +| log | String | ? | **Lastmanagement Gruppen ID** | +| lon | uint8_t | ? | **Lastmanagement: erwartete Anzahl von Ladestationen (derzeit nicht unterstützt)** | +| lof | uint8_t | ? | **Lastmanagement Fallback Amperezahl** | +| loa | uint8_t | ? | **Lastmanagement Ampere** (derzeitiger erlaubter Ladestrom)
wird vom Lastmanagement automatisch gesteuert | +| lch | uint32_t | ? | **Lastmanagement: Sekunden seit letztem Stromfluss bei noch angestecktem Auto**
0 when charging is in progress | +| mce | uint8_t | ? | **MQTT custom enabled**
Verbindung mit eigenen MQTT Server herstellen
0: Funktion deaktiviert
1: Funktion aktiviert | +| mcs | String(63) | ? | **MQTT custom Server**
Hostname ohne Protokollangabe (z.B. test.mosquitto.org) | +| mcp | uint16_t | ? | **MQTT custom Port**
z.B. 1883 | +| mcu | String(16) | ? | **MQTT custom Username** | +| mck | String(16) | ? | **MQTT custom key**
Für MQTT Authentifizierung | +| mcc | uint8_t | ? | **MQTT custom connected**
0: nicht verbunden
1: verbunden Seite | # 3. Kommandos : -Folgende Parameter können nur gelesen werden: - -``` -version rbc rbt car err cbl pha tmp dws adi uby eto wst nrg fwv sse eca ecr -ecd ec4 ec5 ec6 ec7 ec8 ec9 ec1 rca rcr rcd rc4 rc5 rc6 rc7 rc8 rc9 rc1 -``` - -Folgende Parameter können gesetzt werden: - -``` -amp amx ast alw stp dwo wss wke wen tof tds lbr aho afi ama al1 al2 al3 al4 al5 -cid cch cfi lse ust wak r1x dto nmo rna rnm rne rn4 rn5 rn6 rn7 rn8 rn9 rn1 -``` +Parameter mit Zugriffstyp "RW" können gelesen werden, solche mit Zugriffstyp "RO" können nur gelesen werden. ### Parameter setzen