Configuration

Overview

When working with connectors on Industrial Edge, the Databus app is required to exchange the data via MQTT. The configuration of the connectors is done via the Common Configurator app. Therefore also the Registry Service app is necessary, to find installed connectors on an Industrial Edge Device.

Make sure the following apps are installed and running on the Industrial Edge Device (IED):

  • Databus
  • Common Configurator
  • Registry Service

Install SLMP Connector

The SLMP Connector app must be available in your IEM catalog. Proceed the following steps to install the app on your IED:

  • open the catalog in the IEM
  • select the SLMP Connector
  • click 'Install'
  • in the tab 'Configurations' click 'Next'
  • in the tab 'Devices' choose your IED
  • click 'Install Now'
  • click 'Install' to allow the installation

app

Configure Databus

The system app Databus is essential to exchange data between a PLC and the IED. The SLMP Connector sends the transfered data to the Databus on the IED. From there the data can be used for further processing.

You need to create a user and one or more topics in the Databus configuration, which cover the SLMP data:

  • ie/m/j/simatic/v1/slmp1/dp for SLMP metadata
  • ie/d/j/simatic/v1/slmp1/dp/# for SLMP data

Therefore follow these steps:

  • open the Industrial Edge Management (IEM)
  • go to 'Data Connections' > Databus
  • select the corresponding IED
  • create the topic ie/# and a dedicated user with username and password ('edge'/'edge'), set permissions to 'Publish and Subscribe'
  • deploy the configuration and wait for the job to be finished successfully

SLMPdatabus

Configure SLMP via Common Configurator

With the Common Configurator, you can configure several connectors and publish the data to the Databus. Therefore, you must enter the Databus credentials within the Common Configurator:

  • open the IED web interface
  • open the app Common Configurator
  • go to the tab 'Settings' and select the menu 'Databus credentials'
  • enter the databus service name: 'ie-databus:1883'
  • in tab 'Data Publisher settings' enter the databus user name and password ('edge'/'edge')
  • in tab 'Data Subscriber settings' enter the databus user name and password ('edge'/'edge')
  • Save the settings

SLMPdatabuscc

As soon as the SLMP Connector is installed and started on the same IED as the Common Configurator, the connector is visible within the configurator. In this example we want to configure a SLMP connection to a Mitsubishi FX5U (iQF) PLC.

Here is an overview of permitted data types for the Mitsubishi iQR/iQF PLCs:

Data type Operand Length
Bool D, M, X, Y, F, B, SB, W, SW, SD, SM, CC, CS, TS, TC, LCS, LCC, STS, STC, LTS, LTC, LSTS, LSTC, L 1 Bit
Int D, CN, W, TN, STN, SW 2 Byte
Word D, TN, CN, SW, STN, W, SD 2 Byte
DInt D, LCN, W, SW, LTN, LSTN 4 Byte
DWord D, LCN, W, SW, LTN, LSTN 4 Byte
Real D, W, SW 4 Byte
LReal D, W, SW 8 Byte
String D, W, SW 1 - 80 characters

The PLC has the following configuration within GX Works 3:

GXWorks_Config

The PLC program looks like the following:

GXWorks_Program

To configure the SLMP Connector, proceed as following:

  • go to the tab 'Get data' and select tab 'Connector Configuration'
  • select the SLMP Connector

SLMPoverview

  • switch to tab 'Tags'
  • choose 'Add data source'
  • configure the PLC accordingly and save

configuration1

  • under column 'Actions' of the newly created PLC, choose 'Add tag'
  • configure the tags accordingly and save

SLMPaddtagnew

  • select the newly created PLC and click 'Deploy' to save the configuration and start the project

SLMPsaveconfignew

  • back on the overview page 'Databus connectors', the status of the SLMP Connector should be shown as connected

Connected

Now data can be transferred via the SLMP connection. Please find more information in the Usage documentation.